If the motor is still giving you a drive stall error, it probably means that you need a new drive. Hi Leah, good question, and I understand. Hi Matt, sound like the bearings have gone bad, and now they are so bad that the shaft has locked up or is binding, and that trips the breaker. Be sure all lines are open, and again check for air leaks. Call Hayward and speak to their tech support people, for more precise advice. So you could cut off the pipe and cap it yes, although it might be worth investigating the repair cost the crack could be just 2 foot below the ground, near the pump/filter. Using a circuit tester, I determined that the timer and the inline switch has power. BLUE WORKS PCB Main Circuit Board Compatible with Hayward Goldline GLX-PCB-Main System Board Visit the BLUE WORKS Store 193 ratings $16999 FREE Returns Available at a lower price from other sellers that may not offer free Prime shipping. I have a new fiberglass pool and ever since I operate it the pump trips the breaker in most cases overnight hours between 2 timing sessions (pump not running). Weve tried everything. View Details Usfitnessfinder.com. also dont forget to connect the bare bonding wire, if you have one. Please help! Water at the base of the pump: 1. could be from a loose pump lid, dripping when the pump is off, 2. could be a leaking outlet pipe fitting, oozing from where water leaves the pump, and running down the sides of the volute, and dripping off the bottom, or 3. could be the shaft seal failing, behind the impeller. If valve is open when it should be closed the heater will shut down and go into lockout. I just had a pool built for me. They have never had this issue in the pass, a salt water chlorinator was added to the system last year with no problems. Is the replaced pump and motor problem? No lubricant is needed for spider gaskets. 2. Do you believe I have a bad breaker? "headline": "Hayward Pool Heater Troubleshooting",
Not sure whats wrong. Hope thats not the case. I dont want to pay someone to come out & charge me more for not knowing what Im doing. It need not be a fancy $100 meter, it can be a $10 meter from Radio Shack. I tried starting again one morning but the pump wont start. Hi we have a Hayward DE filter for a 2040 in ground. I have a Hayward Power-Flo Matrix and seems to be working fine when it is running the pool. How to Read and Adjust the Hayward Aqua Rite SCG Operational Values. My 2 year old 1.5 HP above ground Hayward pool pump worked fine last year. For a better experience, please enable JavaScript in your browser before proceeding. HI, that is usually a weak motor capacitor, which is a battery used to help the motor get up to 3450 RPM quickly. Hi Carl, check for an air leak in front of the pump on the suction manifold, or around the pump lid, or on around the threads of the fitting that screws into the pump. A visual tip-off is something that is dripping water when the pump is OFF, or that sprays water for half-a-second at the instant the pump shuts off, is drawing air in, when the pump is runnning. Any ideas as to how to fix this? Trying not to damage impeller. It could also be a loose switch in the back of the motor. Hi Virgil, the time clock may not be set, or if you have a controller, the on/off program may not be setup, so it runs until it is set to turn off but is not set to turn back on again? How To Identify The Problem Look at all the metal components in and around your swimming pool. Check the shaft, to see that it is spinning freely, then check the wiring to be sure no bare wires are touching bare metal, or each other, or is corroded, and that all wiring is tight and clean. Its just a trickle (as opposed to a spray)at this time. Overheating pumps are usually DOA, in my experience, but there may be hope. The motor eventually started. As soon as I hook it up and it starts pumping water the pump slows down and struggles, the sound is very noticeable. After about 15minutes the pump stopped and the motor was super hot. Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. Any ideas on what may be going on? "caption": "In The Swim Blog"
It seems the pump is more powerful than last year ? I backwashed and started again and it was good for another 24 hours and the circulation stopped again and the pressure reached max. The burnt odor is not a good sign a new motor may be needed soon! I had an old hayward 1.5 hp power flo matrix 2 speed pump. If it does not, keep reading. When he went to turn the pool back on it made a slight humming noise like it was trying to come back on but it wouldnt turn on. So my Hayward melted the whole left sided plastic shrouds. I purchased a SP1580X15 Hayward pump July 2016 and began using it this year 2017. There is an o-ring on the union, and also on the valve stem, and they can start leaking over time. Might be 2-years here is a chart on reading Hayward serial numbers, to find date of manufacture https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, I have to reprime my hayward pump everytime I turn it on. There could also be a short in the wiring to the pump, or from the breaker to the switch. A check valve could also be a solution, but a Drain King is different, they are used to pressure lines, for blowing out clogged drains usually, but also useful to pressurize the suction manifold to look for air leaks, or for priming a pump that has issues catching prime. How can I locate and check if a valve is faulty. You can plug the pump into a long extension cord and test it with another outlet on the house, to rule out problems with the outlet its plugged into now. It is a H400FDN series. Seems to take away the point of getting a variable speed pump if we have to run it on high all the time. Checked to see that there was no short in the wire with an ohms meter . Please ignore my previous question I put a slight bend in the end of the wrench and was able to get a grip on the shaft , When I opened my pool the pump hummed and did not start. That is usually suitable, but 20 amp could also be used. Our switch seems to be getting power- a voltage tester confirms this but pump makes zero sound when switch is turned on. If it is reversible is lists voltage on the label as 115V/230V, but if 230V only, it just says 230V. presto, all working good! Upon resetting an electrical short sound came from the pump motor tripping the breaker a second time. 1. We had this issue with our older Hayward pump near the end of its life, but it would throw the breaker every time we tried to start the pump near the end of the summer last year. I just purchased a pool home that is utilizing a Hayward Northstar SP4020NS I have noticed that when the pump shuts off water briefly blows out of the strainer cover, like a pressure release. The capacitor is at 9 oclock and the thermal regulator at 12 oclock. Hi, we just installed a new AquaRite unit and it has been running for 48 hrs The salt level is 3100 ppm (pool store also confirmed and tested the water, no issues detected with the water). Fourth, could be a clog or obstruction AFTER the pump, in the filter valve, or in the filter itself. Is there a trick to moving it to 115? Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have We would like to show you a description here but the site wont allow us. Hi Sara, could the sound be the gas whistling thru the burner orifices? Good day everyone. larger hp motors, are not reversible. I came back after going out and my older Hayward pump was off. Reset the average salt level on startup and whenever you replace your cell. Remove the cover plate, and use an insulated screwdriver to discharge the capacitor. I have it set on a timer and when the pump comes on the flow rate is good but as the day goes on it becomes less and less. I have a Hayward pump that will backwash but nothing else. Check all wires, to be sure that the metal ends of wires are not touching any metal ends of the motor housing, or contacting other wire metal ends.
Our pump wont start at all after opening the pool. Power on LED is intermittently on or off. You could also use a Hayward 24 sand filter, item E3324. Motors that are reversible always ship from the factory at 230V, and need to be manually switched to accept 115V. Likely not a problem with the pump itself. Also make sure that the pump has no air leaks from loose pipes, loose pump lid, low water level in pool For you Scott, the next step is to shut off power to pump and remove the Blue, Black and Red wires (page 4 owners manual) from the drive and check each motor lead to ground. Read up on it and seems it happens a lot and the motor drive needs to be replaced. Override this by moving the Main Switch to Super Chlorinate. Hi i have a Hayward super pump when I turn it on it doesnt suck any water from the pool the filter pressure gauge is at 0 when I turn it off it makes a spinning noice. Check electrical connections and wiring for loose or broken. Just push the red button back in. A click on the outlet you say? Thanks. When I take the lid off the pump hopper I can hear the air releasing, and there cant be any air leaks anywhere as its a new line right from the pump directly into the pool. My Hayward Pump Super shuts off and then starts then shuts off and then starts again. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs.
How to Reset Inspect Cell Light - Hayward POOLSIDE Blog My Hayward pump II LX 1.5 horsepower. If all good, check the capacitor, at 9 oclock, looking for bulging or cracking or burned marks. Inspect the capacitor (black cylinder, 9 oclock) and the centrifugal switch, (on the end of the motor shaft), for any signs of damage or looseness. Hi, it is either an air leak (a non-issue if installed below water level), or the suction pipes are too small for the pump size, or the hose may be collapsing inward under pressure. https://twitter.com/inyopoolsFOLLOW us on INSTAGRAM! One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. Turned it off tho clear the skimmer basket.. water level is correct. I dont know if Im convinced the new pump is bad or not, or if I need higher voltage to the pump. If the problem continues after fixing the problems above, you may have a clog in the suction side of your pump. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Drain plugs, pump lid, pipe coming into pump, skimmer or main drain valves, low water level, stuck skimmer weir, or the dreaded underground cracks in pipe (rare problem). Hi Rodney, well the Green wire should be ground, so that eliminates one choice. Still the same results. We just has this pool installed year, and brought the motor inside the house. I cannot locate the model # on either but believe the filter is a c250. It was off this morning and I reset the breaker. "caption": "In The Swim Blog"
If there is an external 2-speed timeclock, check the wiring, esp. Check the breaker inside the house, make sure its not tripped. Sanitization, Learn About What seems to be the problem. New pump probably not a shaft seal problem, just loose clamp band or volute bolts. Hi Brian, is this a DE filter? If it clogs up again, you will need to break it down and manual clean, then soak in DE Filter Cleaner not so hard and the best cleaning, just a lot of little nuts and washers to remove and replace. I will also say that a truly drip-proof pool system is not really the norm, most filter systems with a few years on it will ooze and drip here and there, and most often its of little concern. Worn bearings can also create enough heat to trip the switch. Check the motor vent holes, (bottom front) to be sure they are not clogged. Holding the shaft stationary (so it wont turn), unthread the impeller, counter clockwise, to remove. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. Before purchasing the new pump, I replaced the breaker just to be safe, but it is still throwing the new one. On a Hayward pump with clogged impeller, you can remove the basket, reach through the small hole with your fingers (pump off! Automatic reset is immediate after the switch closes, Blower vacuum switch open when expected closed error. "wordCount": "1194",
I get home from work and the pump is running. Hi Joe, I would first suspect an air leak, Superpumps can also draw air from a loose drain plug and easily around the square lid gasket but the usual suspect is the pipe coming into the pump. The sound you reference pumping rocks sounds like a pump that is cavitating, or starved for water. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
3. It could also be something loose inside of the tank. Another oddity is both failure are upon Spring re-opening,and the pumps ran flawlessly throughout each summer? could that be a GFCI tripping? Mine hums and then trips the breaker. Could be the use of a clarifier or flocculent that is clogging the sand? My Hayward pump is only about 3 yrs old. I put a new power cord socket in the water proof box, which feeds power to the pump, I shined up the power cord plug pins), (power cord is about 2.5 ft of 12 Ga, not wet, not laying on the ground) Shaft seal went out twice and I have a groove in the motor shaft now. If the motor was submerged, it may not recover. Thank you so much for taking time to answer all our concerns. Or maybe the glue that Im assuming is no longer working? What is happening is that the pump pulls so hard that either an air leak around the pump develops, or the vacuum hose or pool to pump hose begins to crimp and collapse. Could be loose fitting on hoses. The blower will run until error condition is corrected. Check the tightness on all wire connections, on the breaker, timeclock and motor. Hi Carolyn, When a pump displays those symptoms, its usually an air leak or a collapsed suction hose, or a very dirty filter. What are the amp and volt readings for the new cell? Finally, it could be bad voltage, but again, it was running before just fine, so probably not that. If you havent inspected your cell yet, now is aperfect time. If you have a local electric motor shop in town, you could drive your motor over there for testing. Hi Andy, good question thanks Motor will start on low, but not on high. Armstrong Human Resource Management 13th Edition Pdf, We have parts for the Super pump. If there is no motor sound at all, and the breaker trips, it could be a bad motor, or it could be a bad breaker, they wear out, especially if used often (instead of the timer switch). Then restarts. IF thats good, check the pipe coming into the pump, does it drip when the pump is off? Is the shaft spinning freely? bought a SP2610x152s super pool pump 1.5 hp. They function as the starting battery for the motor, to help it get up to speed quickly. If the motor label says 115V/230V it is reversible, but if it says just 230V, Hi Chad, Could be dangerous! Thanks The Pool is a Roman 23 in ground. Hi Tammy, could be many things. Not it says drivererror pump stalled. Be sure though, that the motor has plenty of air flow, and the air flow vents are not blocked, and that incoming voltage is not too high or too low. Not all horsepowers are created equal, meaning that a 1hp Hayward Super II pumps a lot more water than a 1hp Hayward Super I, or Max-Flo. We were cleaning our pool filter one day and went to restart the pump and it didnt. A corroded part will be rusted and will start to disintegrate over time. What can I do? Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. I have a t-15 cell. As I started to prep for this season, I did notice that the positive and negative electrical terminals on the 3 prong cord were corroded and loose. Electrical hooked up by electrician help!! Shut it off & starting looking for help online. Anything else to fiddle with or bad motor? If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. When the centrifugal switch is pushed flat by the spinning shaft (or with your finger [power off! When turned on, it clicks in and off every few seconds. Any ideas or what else to check? Not normal, but cant see a reason why that would cause the seal to fail. This one is 5 years old. IE9 and older versions are not supported. Loose connection inside the plug or socket. Its running now but when I turn it off it wont restart. Automatic restart 2 min after error is corrected. hayward blue essence troubleshootingpeel and stick tile 914665 hayward blue essence troubleshooting. Low speed should be enough flow to activate the flow switch. When I installed the filter and pump the water in the filter came gushing out of the filter and the top mount was raised up even though the clamps were tightly screwed in place. While distracted pouring the Blue Nun, This Week missed the irony that in the decade Japan opened its first Shinkansen Bullet train route Britain was running down and closing main lines.